Important: EM2 test-stand hardware components are NOT compatible with hardware supplied for EM1 test-stands. Do not mix TEM/TEM-PS/Transition Card EM1 with EM2 hardware. Hardware for EM2 is marked "EM2" on the TEM, TEM-PS, VME Transition Card and LCB supplied.
Documents:
The documents are in the process of being transferred to the LAT-DOC system for official release, please retrieve them from LATDOC's.
Here are applicable document numbers and selected copies of the documents in the release cycle (use them with caution).
Note that we do not perform impedance/short/open/voltage measurements on all pins, but test functionality of the system. The "safe-to-mate" test is the responsibility of the sub-system.
Tracker:
EGSE-TKR TESTSTAND #9
LAT Quality Assurance |
|||
|
|||
| The following Nonconformance Report # 00285 was submitted on 01/19/05 12:26:07 | |||
| Entered by Ludvik, Jeffrey - jsludvik@slac.stanford.edu | |||
| Found by: Customer Complaint | Type of Nonconformance: Minor | ||
| Discrepancy Level: Non-Flight Hardware | Sub-System: Electronics (ELEC) | ||
| Item Description: EGSE TRKR 9 TEM/TPS | |||
| Supplier: | Location: | ||
| Drawing/Rev #: | Lot/Heat #: | Serial #: TEM GLAT0494, TPS GLAT1230 | Test Procedure/Rev #: |
|
Description of Nonconformance:
INFN described the problem as: The SCMD loop on GTCC 2 is
apparently screwed up (the levels are 2.21 V on SCMDP and 2.05 V
on SCMDN on that cables, while the usual is 1.30-1.10). It's
impossible to communicate with the TKR front end electronics on
cable 2 (we tried with a non-flight MCM). The TEM/TPS is at SLAC
for repair. |
|||
| Disposition Area | |
| Defect Code: |
Disposition: (Valid dispositions: Rework, Repair, Use-as-is, Reclassify, Return to Vendor, Scrap, or Documentation Change) |
| Disposition Instructions: | |
| Root Cause: | |
| Action taken to Preclude Recurrence of Discrepancy: | |