Open I&T Test NCRs
Rev. 8/2/05 L.Wai
NCR# date opened description of problem and completed activities status
281 1/16/2005 12:00 FMA AVDDB current is 176mA for C45 (out of family); TKR says use-as-is QA reviewing closure OK to break config
297 1/29/2005 18:45 TE702 trigger jitter > 250 ns  Su Dong to re-define spec OK to break config
373 3/9/2005 17:00 Didn't use GASU EGSE for CAL CPT; procedure modified to use GASU OK to close
432 4/15/2005 8:05 Resistance to ground >2.5mOhm for FMA & FMB need MRB to close OK to break config
443 4/27/2005 16:53 CAL fle threshold setting difficulties in trigger tests due to high rates same solution as NCR 590 OK to break config
458 5/10/2005 9:07 vhdl bug in TEM;very low error rate; Gunther says "use as is" needs writeup by Mike OK to break config
477 5/16/2005 14:22 analysis of TEM FIFO overflow error events for unexpected events Leon is looking at this OK to break config
487 5/23/2005 17:24 CAL register test failure; Ric thinks it's housekeeping interference need elevated MRB OK to break config
509 6/6/2005 9:59 deferred 4-tower tests to 6-towers; completed now OK to close
510 6/6/2005 10:06 SVAC data w/o GEM contrib due to EGSE config error; procedure modified OK to close
529 6/16/2005 13:51 TKR GTFE readback error in bay 9; freq. scans done; res. Meas. Done no more action for now OK to break config
532 6/16/2005 21:59 TIC mux_config readback error due to housekeeping verified by test need MRB on script mods OK to break config
535 6/20/2005 8:15 Duty cycle margin failure in FM4 (see NCR516, closed TKR NCR) need trend analysis OK to break config
538 6/20/2005 18:18 updated hot strip list was not used for LPT; is now updated;runs retaken OK to close
539 6/20/2005 18:27 TKR trig diag. not latched in TkrDataTaking; schema fixed, runs retaken QA reviewing closure OK to break config
542 6/21/2005 11:24 TE704 failure due to configuration error (LTE-295); fixed w/ LATTE 4.9.1 OK to close
549 6/27/2005 14:53 Tracker alarm over temperature, out of family temps, and telemetry glitches need MRB to close OK to break config
550 6/27/2005 15:24 TEM errors were observed during TE704 test set up; no errors on rerun need MRB to close OK to break config
556 7/6/2005 14:02 LCB to LAT errors due to wrong clock edge used; fixed w/ LATTE 4.9.2 OK to close
560 7/12/2005 8:59 root cause same as that for NCR 569 as determined by analysis QA reviewing closure OK to break config
562 7/14/2005 13:09 GLAT 1752 / 1753 TEM/TPS assys have not been reworked need MRB for dispo OK to break config
569 7/15/2005 10:40 GCCC configuration error;schema fixed, config check tools improved OK to close
576 7/19/2005 16:53 TKR Trig diag. latching not optimized; timing config updated, runs retaken OK to close
590 7/28/2005 15:27 CAL noisy channels (fast shaper) need elevated MRB OK to break config
592 7/29/2005 16:52 thermistors for the odd numbered bays are rotated 180 degrees need MRB to resolve OK to break config