| Two Tower Test Report | ||||
| Rev. 5/13/05 L.Wai | ||||
| Sub-Series | Test | Purpose | Time (hr) | Notes |
| CPT | ELX TEM register test | Check for TEM errors | 0.1 | pass |
| CPT | Aliveness Test | Check for TEM errors | 0.2 | pass |
| CPT | SVAC Test (STR) | Check for offline errors | 1 | pass |
| CPT | TKR CPT (FMA) | 2-tower CPT | 1 | pass |
| CPT | TKR CPT (FMB) | 2-tower CPT | 1 | pass |
| CPT | TE702 (FMA) | 2-tower CPT | 0.5 | fail (NCR297) |
| CPT | TE703 (FMA) | 2-tower CPT | 0.5 | can't execute (NCR416) |
| CPT | TE704 (FMA) | 2-tower CPT | 0.5 | pass |
| CPT | TE702 (FMB) | 2-tower CPT | 0.5 | fail (NCR297) |
| CPT | TE703 (FMB) | 2-tower CPT | 0.5 | can't execute (NCR416) |
| CPT | TE704 (FMB) | 2-tower CPT | 0.5 | pass |
| CPT | CAL CPT (FM104) | 2-tower CPT | 1.5 | pass |
| CPT | CAL CPT (FM105) | 2-tower CPT | 1.5 | pass |
| TRIGGER | TREQ scan | TREQ alignment | 1.5 | pass |
| TRIGGER | TACK scan | TACK optimization | 8 | pass |
| TRIGGER | Efficiency | perf. on vertical tracks | 1.5 | pass |
| TRIGGER | Efficiency w/ paddle offset | perf. on wide angle | 1.5 | pass |
| TRIGGER | Stretch-OR / One-Shot (STR) | perf. Study | 8 | pass |
| CALIB | CalibDac (FM104) | CAL calibration | 2 | pass |
| CALIB | MuTrig (FM104) | CAL calibration | 4 | pass |
| CALIB | CalibGen (FM104) | CAL calibration | 1 | pass |
| CALIB | CalibDac (FM105) | CAL calibration | 2 | pass |
| CALIB | MuTrig (FM105) | CAL calibration | 4 | pass |
| CALIB | CalibGen (FM105) | CAL calibration | 1 | pass |
| CALIB | TE601/602/604 (FMA) | TKR calibration | 2 | pass |
| CALIB | TE601/602/604 (FMB) | TKR calibration | 2 | pass |
| CSPT | CSPT (STR) | combined system perf. | 3 | pass |
| E2E | e2e 1-1 | e2e basic cosmics | 1 | pass |
| E2E | e2e 2-3 | e2e basic cosmics | 1 | pass |
| E2E | e2e 2-6 | e2e basic cosmics | 1 | pass |
| E2E | e2e 2-7 | e2e basic cosmics | 1 | pass |
| E2E | e2e 3-1 | e2e basic cosmics | 1 | pass |
| E2E | e2e 3-2 | e2e basic cosmics | 1 | pass |
| E2E | e2e 7-1 | e2e basic cosmics | 1 | pass |
| E2E | e2e 2-1 | e2e S/C power margin | 1 | pass |
| E2E | e2e 2-2 | e2e S/C power margin | 1 | pass |
| E2E | e2e 4-1 | e2e nominal rate test | 1 | pass |
| E2E | e2e 8-6 | e2e nominal rate test | 1 | pass |
| E2E | e2e 4-2 | e2e nominal rate test | 1 | pass |
| E2E | e2e 4-3 | e2e nominal rate test | 1 | pass on re-run (NCR458) |
| E2E | e2e 5-3 | e2e nominal rate test | 1 | pass |
| E2E | e2e 5-6 | e2e nominal rate test | 1 | pass |
| E2E | e2e 5-7 | e2e nominal rate test | 1 | pass |
| E2E | e2e 8-8 | e2e nominal rate test | 1 | pass |
| E2E | e2e 4-4 | e2e nominal rate test | 1 | pass |
| SVAC | e2e B-2 | SVAC data collection | 4 | pass |
| SVAC | e2e B-10 | SVAC data collection | 15 | pass |
| SVAC | e2e B-13 | SVAC data collection | 1 | pass |