Two Tower Test Report
Rev. 5/13/05 L.Wai
Sub-Series Test Purpose Time (hr) Notes
CPT ELX TEM register test Check for TEM errors 0.1 pass
CPT Aliveness Test Check for TEM errors 0.2 pass
CPT SVAC Test (STR) Check for offline errors 1 pass
CPT TKR CPT (FMA) 2-tower CPT 1 pass
CPT TKR CPT (FMB) 2-tower CPT 1 pass
CPT TE702 (FMA) 2-tower CPT 0.5 fail (NCR297)
CPT TE703 (FMA) 2-tower CPT 0.5  can't execute (NCR416)
CPT TE704 (FMA) 2-tower CPT 0.5 pass
CPT TE702 (FMB) 2-tower CPT 0.5 fail (NCR297)
CPT TE703 (FMB) 2-tower CPT 0.5  can't execute (NCR416)
CPT TE704 (FMB) 2-tower CPT 0.5 pass
CPT CAL CPT (FM104) 2-tower CPT 1.5 pass
CPT CAL CPT (FM105) 2-tower CPT 1.5 pass
TRIGGER TREQ scan TREQ alignment 1.5 pass
TRIGGER TACK scan TACK optimization 8 pass
TRIGGER Efficiency perf. on vertical tracks 1.5 pass
TRIGGER Efficiency w/ paddle offset perf. on wide angle 1.5 pass
TRIGGER Stretch-OR / One-Shot (STR) perf. Study 8 pass
CALIB CalibDac (FM104) CAL calibration 2 pass
CALIB MuTrig (FM104) CAL calibration 4 pass
CALIB CalibGen (FM104) CAL calibration 1 pass
CALIB CalibDac (FM105) CAL calibration 2 pass
CALIB MuTrig (FM105) CAL calibration 4 pass
CALIB CalibGen (FM105) CAL calibration 1 pass
CALIB TE601/602/604 (FMA) TKR calibration 2 pass
CALIB TE601/602/604 (FMB) TKR calibration 2 pass
CSPT CSPT (STR) combined system perf. 3 pass
E2E e2e 1-1 e2e basic cosmics 1 pass
E2E e2e 2-3 e2e basic cosmics 1 pass
E2E e2e 2-6 e2e basic cosmics 1 pass
E2E e2e 2-7 e2e basic cosmics 1 pass
E2E e2e 3-1 e2e basic cosmics 1 pass
E2E e2e 3-2 e2e basic cosmics 1 pass
E2E e2e 7-1 e2e basic cosmics 1 pass
E2E e2e 2-1 e2e S/C power margin 1 pass
E2E e2e 2-2 e2e S/C power margin 1 pass
E2E e2e 4-1 e2e nominal rate test 1 pass
E2E e2e 8-6 e2e nominal rate test 1 pass
E2E e2e 4-2 e2e nominal rate test 1 pass
E2E e2e 4-3 e2e nominal rate test 1 pass on re-run (NCR458)
E2E e2e 5-3 e2e nominal rate test 1 pass
E2E e2e 5-6 e2e nominal rate test 1 pass
E2E e2e 5-7 e2e nominal rate test 1 pass
E2E e2e 8-8 e2e nominal rate test 1 pass
E2E e2e 4-4 e2e nominal rate test 1 pass
SVAC e2e B-2 SVAC data collection 4 pass
SVAC e2e B-10 SVAC data collection 15 pass
SVAC e2e B-13 SVAC data collection 1 pass