Four Tower Test Report
Rev. 6/16/05 L.Wai
Sub-Series Test Purpose Notes
Bay 4 TKR LPT ELX TEM register test Check bay 4 DAQ cables pass
Bay 4 TKR LPT Aliveness Test (NCR420 dispo) bay 5 post-integration test not run (NCR420 dispo modified)
Bay 4 TKR LPT TKR LPT (NCR420 dispo) bay 5 post-integration test pass
Bay 5 CPT ELX TEM register test bay 5 post-integration test pass
Bay 5 CPT Aliveness Test bay 5 post-integration test not run (not required)
Bay 5 CPT TKR CPT bay 5 post-integration test conditional pass
Bay 5 CPT CAL CPT bay 5 post-integration test pass
Bay 0 TKR LPT ELX TEM register test bay 1 post-integration test pass
Bay 0 TKR LPT Aliveness Test (NCR420 dispo) bay 1 post-integration test not run (NCR420 dispo modified)
Bay 0 TKR LPT TKR LPT (NCR420 dispo) bay 1 post-integration test pass
Bay 1 CPT ELX TEM register test bay 1 post-integration test pass
Bay 1 CPT Aliveness Test bay 1 post-integration test not run (not required)
Bay 1 CPT TKR CPT bay 1 post-integration test conditional pass
Bay 1 CPT CAL CPT bay 1 post-integration test pass
LAT CPT ELX TEM register test Check for TEM errors pass
LAT CPT Aliveness Test Check for TEM errors conditional pass
LAT CPT e2e 1-3 (STR 11) Check for offline errors pass
TRIGGER TREQ scan (Bay 5) TREQ alignment pass
TRIGGER TREQ scan (Bay 1) TREQ alignment pass
TRIGGER TACK scan TACK optimization pass
TRIGGER Efficiency perf. on vertical tracks deferred per NCR509
TRIGGER Efficiency w/ paddle offset perf. on wide angle deferred per NCR509
LAT CPT LAT CPT (TKR Section) 4 Bay CPT bays 0,4 CPTs deferred per NCR509
LAT CPT LAT CPT (CAL Section) 4 Bay CPT bays 0,4 CPTs deferred per NCR509
LAT CPT TE702,704 (FM1) TKR Performance Test deferred per NCR509
LAT CPT TE702,704 (FM2) TKR Performance Test deferred per NCR509
LAT CPT LAT LPT (14 MHz) Clock Margin Test fail (NCR505, dispo is to eliminate test)
LAT CPT LAT LPT (22 MHz) Clock Margin Test fail (NCR505, dispo is to eliminate test)
CALIB TKR Calib. (STR 10) TKR calibration pass
CALIB CalibDac (FM102) CAL calibration pass
CALIB CalibGen (FM102) CAL calibration pass
CALIB MuTrig (FM102) CAL calibration pass
CALIB CalibDac (FM103) CAL calibration pass
CALIB CalibGen (FM103) CAL calibration pass
CALIB MuTrig (FM103) CAL calibration pass
CALIB TE601/602/604 (FMA) TKR calibration pass
CALIB TE601/602/604 (FMB) TKR calibration pass
CALIB TE601/602/604 (FM1) TKR calibration pass
CALIB TE601/602/604 (FM2) TKR calibration pass
CALIB e2e 1-1 (1 minute) Configuration Validation pass
E2E e2e 4-4 (NCR458 pend,20KHz trig.) High Rate Test not run (NCR458 dispo not modified)
SVAC e2e B-13 SVAC data collection pass
SVAC e2e B-2 SVAC data collection pass
SVAC e2e B-10 SVAC data collection pass