| Eight Tower Test Report (pre-ACD and pre-FSW) - request to break configuration | ||||
| Rev. 8/23/05 L.Wai | ||||
| Sub-Series | Test | Purpose | P/F | Notes |
| EICIT | Bay 12 DAQ Cable EICITs | bay 12 post-integration test | pass | |
| EICIT | Bay 13 DAQ Cable EICITs | bay 13 post-integration test | pass | |
| LAT CPT | TEM register test - redundant (8-bays) | Check for TEM errors | pass | per NCR529 (old) |
| LAT CPT | TEM register test - primary (8-bays) | Check for TEM errors | pass | per NCR529 (old) |
| LAT CPT | TkrSimOcc (8-bays) | Set TKR occ. for CAL CPT | pass | |
| LAT CPT | LAT CPT - TKR Section (8-bays) | 8 Bay CPT | pass | per NCR604,605,617,357 (old) |
| LAT CPT | LAT CPT - CAL Section (8-bays) | 8 Bay CPT | pass | per NCRs 607, 608, 609 |
| LAT CPT | TE702 (8-bays) | FM4, FM6 Performance Test | pass | per NCR297 (old) |
| LAT CPT | TE704 (8-bays) | FM4, FM6 Performance Test | pass | |
| TRIGGER | FLE Threshold minimization (Bay 12) | reduce walk in CAL FLE | pass | |
| TRIGGER | TREQ scan (Bay 12) | TREQ alignment | pass | |
| TRIGGER | FLE Threshold minimization (Bay 13) | reduce walk in CAL FLE | pass | |
| TRIGGER | TREQ scan (Bay 13) | TREQ alignment | pass | |
| TRIGGER | TACK scan (Bays 12, 13) | TACK optimization | pass | memory use prob. for 8-bays |
| TRIGGER | Efficiency | perf. on vertical tracks | pass | |
| TRIGGER | Efficiency w/ paddle offset | perf. on wide angle | pass | |
| CALIB | CalibDac (8-bays) | CAL calibration | pass | |
| CALIB | CalibGen (8-bays) | CAL calibration | pass | |
| CALIB | MuTrig (8-bays) | CAL calibration | pass | |
| CALIB | TE601 (8-bays) | TKR calibration | pass | |
| CALIB | TE602 (8-bays) | TKR calibration | pass | |
| CALIB | TE604 (8-bays) | TKR calibration | pass | |
| SVAC | e2e B-2, B-10, B-13 (1 minute ea.) | Configuration Validation | pass | per NCR477 (old) |
| SVAC | e2e B-13 (1 hour) | SVAC data collection | pass | per NCR477 (old) |
| SVAC | e2e B-10 (15 hours) | SVAC data collection | pass | per NCR477 (old) |
| SVAC | e2e B-2 (4 hours) | SVAC data collection | pass | per NCR477 (old) |
| NCR604 | LAT CPT - TKR section, lights off | check for light leaks | pass | only analyze earlier failed bays |
| NCR605 | Bay 9 TKR CPT | run control crash | pass | pass on hippodraw fixes |
| Sign-off: | I&T Management | _____________________ | ||
| Systems Engineering | _____________________ | |||
| Quality Assurance | _____________________ | |||