The official data taking period was from SEP 27,2003 to OCT12, 2003 when  CAL and TKR were integrated into the single bay grid.

The Cosmic Ray Data was taken in the following configurations

 

CONFIGURATION

EXPERIMENTAL SET-UP

TRIGGER

CAL

TKR

COMMENTS

 

 

 

 

 

 

Default

tower in

vertical orientation

scintillator telescope with 50 cm of Pb below CAL 

CAL-LO

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT disabled

 

A

tower in

vertical orientation

no Pb

CAL-LO

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT disabled

Several runs with TACK delay at different values

B

tower in

vertical orientation

No Pb

TKR

3-IN_A_ROW

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT disabled

Several runs with TACK delay at different values

C

tower in

vertical orientation

scintillator telescope with 50 cm of Pb below CAL 

TKR

3-IN_A_ROW

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT disabled

 

D

tower in

horizontal orientation

 

TKR

3-IN_A_ROW

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled

Several runs with TACK delay at different values

E

tower in

vertical orientation

No Pb

EXTERNAL

(scintillator tiles)

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT disabled

Several runs with TACK delay at different values

F

tower in

vertical orientation

scintillator telescope with 50 cm of Pb below CAL 

EXTERNAL

(scintillator tiles)

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT disabled

Several runs with different external trigger delays and fixed nominal TACK delays for CAL and TKR

 

 

The Van de Graaff Data was taken in the following configurations

Low energy photons (~20 MeV) were taken from OCT 7 to OCT 9, 2003

 

CONFIGURATION

EXPERIMENTAL SET-UP

TRIGGER

CAL

TKR

COMMENTS

 

 

 

 

 

 

Default

tower in

horizontal orientation photons impinging on top face of tracker

 

TKR

3-IN_A_ROW

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled

There is a steel window (~7% radiation lengths) at the end of the VDG pipe to keep the vacuum

A

tower in

horizontal orientation

photons impinging on top face of tracker

added a 28% Pb shield after the beam pipe

 

TKR

3-IN_A_ROW

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled

There is a steel window (~7% radiation lengths) at the end of the VDG pipe to keep the vacuum 

B

tower in

horizontal orientation

photons impinging on bottom of tracker ~ 135 deg from vertical

 

TKR

3-IN_A_ROW

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled

There is a steel window (~7% radiation lengths) at the end of the VDG pipe to keep the vacuum 

C

tower in

horizontal orientation

photons impinging on bottom of tracker ~ 135 deg from vertical

 

CAL-LO

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled

 

D

tower in

vertical orientation

photons impinging on the side of CAL (covering about 2-3 crystal layers)

 

CAL-LO

 

nominal Thresholds (~8 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled

 

E

tower in

vertical orientation

photons impinging on the  side of CAL (covering about 2-3 crystal layers)

 

CAL-LO

 

Low Thresholds (~4 MeV/crystal)

Non zero suppression

4 range readout

TACK delay 60 x 50 ns = 3000ns

nominal Thresholds

(~0.3 MIPs = DAC 30 range 0)

TACK delay 0 x 50 ns = 0ns

TOT enabled